Radio battery-runtime calculator: inputs, examples and limitations
By CumbriaCQ · Updated and source checked
Battery runtime
Estimate operating time from capacity, load and duty cycle.
--
Cumbria emergency contacts
Immediate danger or a life-threatening emergency? Call 999 or 112. CumbriaCQ is not an emergency service.
For NHS advice, police non-emergencies, power cuts, gas, water, flooding and help from either local council, use our Cumbria emergency contacts directory. It covers Cumberland and Westmorland and Furness.
This calculator estimates how long a battery could power a radio or other DC load. It includes both active/transmit current and receive/idle current, so a radio left listening is not treated as switched off between transmissions. The answer is a planning estimate, not a measured runtime or a promise of communications.
How the estimate works
Average current = active current × duty cycle ÷ 100 + idle current × (1 − duty cycle ÷ 100). Then runtime in hours = capacity in Ah × usable percentage ÷ 100 ÷ average current in A. The result is rounded to one decimal hour. The tool does not automatically calculate voltage conversion, inverter losses or battery ageing.
Fill in the five inputs
- Battery capacity, amp-hours (Ah): use the whole pack's capacity. Divide mAh by 1,000 to get Ah: 2,000mAh is 2Ah. A watt-hour (Wh) figure is not an Ah figure.
- Load/active current, amps (A): enter current drawn from the battery during the active period, such as transmitting. This is not the radio's RF output power in watts.
- Duty cycle, per cent: the proportion of time at active current. Use 100% for a continuous load or an already calculated average. Use 0% to model listening only, with a positive idle current.
- Usable capacity, per cent: the portion you plan to use after retaining a reserve and allowing for the battery's limits. The example's 80% is an assumption, not a safe universal depth of discharge.
- Receive/idle current, amps: current drawn during the remainder of the time. Zero means genuinely switched off; enter the real receive draw for a radio kept listening.
Capacity and current must refer to the same battery side of the system. If a converter changes voltage, its output current is not the battery current. Use a suitable battery-side measurement or a Wh/W energy budget with explicit losses. See power-station energy and output planning.
Worked examples
A continuous 2A load
Enter 20Ah, 2A active, 100% duty, 80% usable and 0A idle. Usable capacity is 16.0Ah, average current 2.00A and the result 8.0 hours. At 100% duty the idle value has no effect.
A genuinely switched-off load
Enter 20Ah, 10A active, 25% duty, 80% usable and 0A idle. Average current is 2.50A and runtime 6.4 hours. This assumes zero current during the remaining time. Change idle to 1A: average current becomes 3.25A and the estimate falls to 4.9 hours.
A radio transmitting and receiving
Suppose transmit draw is 5A for 10% of the time and receive draw 0.5A for the remaining 90%. Enter 20Ah, 5A active, 10% duty, 80% usable and 0.5A idle. Average draw is (5 × 0.10) + (0.5 × 0.90) = 0.95A. The estimate is 16.8 hours. Omitting receive draw would incorrectly suggest 32.0 hours.
For three or more operating states, calculate a weighted battery-side average using time fractions covering the whole period, then enter that current with 100% duty. These are numerical examples, not tests of a named radio or battery.
Why real runtime can be shorter
- Age, temperature, state of charge and manufacturing tolerance affect available capacity.
- Lead-acid capacity varies with discharge rate; this calculator does not model the Peukert effect.
- Low voltage, transmit peaks, cable voltage drop and battery-management cutoffs can stop equipment before the battery is nominally empty.
- Converters, displays and accessories consume energy. Include their battery-side draw or leave an appropriate allowance; do not count the same loss twice.
- Transmit power, receive volume, scanning and sleep settings change current. A manufacturer's runtime may assume a different operating pattern.
Follow the equipment and battery makers' voltage, chemistry, charging, temperature and protection instructions. Victron's model-specific charging guidance illustrates why the correct battery settings matter; it is not a universal prescription for another battery. Leave reserve and conduct a safe representative test before relying on a setup.
Invalid inputs and privacy
Capacity and active current must be positive. Duty must be 0–100%; usable capacity must be greater than zero and no more than 100%; idle current cannot be negative. Blank or invalid inputs replace the estimate with a correction message rather than retaining an old answer. Zero average current has no finite runtime estimate. Inputs stay in this browser and are not stored or sent by this tool.
Without JavaScript, use the formula and examples above; the interactive estimate requires JavaScript. Continue with safe solar charging or the amateur-radio learning route. Enough battery power does not establish transmit permission or a usable radio path.
Your next step
Explore Power & Communications · Ask the CumbriaCQ community
Sources and further reading
- CumbriaCQ calculator implementation
- CumbriaCQ battery-runtime calculator
- Victron MPPT manual: configuration and settings
Source links were checked for this update. Official instructions and manufacturers’ guidance take precedence. How these guides are prepared.